C.2 C.2.3 Defaults by Card
Table C-3 DS-3 Card Default Settings
Default Name Default Value Default Domain
DS3.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00
DS3.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft
DS3.config.SDBER 1E-7 1E-5, 1E-6, 1E-7, 1E-8, 1E-9
DS3.config.SFBER 1E-4 1E-3, 1E-4, 1E-5
DS3.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS
DS3.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700
DS3.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900
DS3.pmthresholds.line.nearend.15min.LOS
S
10 (seconds) 0 - 900
DS3.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900
DS3.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200
DS3.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400
DS3.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400
DS3.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400
DS3.pmthresholds.sts.farend.15min.CV 15 (G1 count) 0 - 2160000
DS3.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900
DS3.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72
DS3.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900
DS3.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900
DS3.pmthresholds.sts.farend.1day.CV 125 (G1 count) 0 - 207360000
DS3.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400
DS3.pmthresholds.sts.farend.1day.FC 40 (count) 0 - 6912
DS3.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400
DS3.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400
DS3.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000
DS3.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900
DS3.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72
DS3.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900
DS3.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900
DS3.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000
DS3.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400
DS3.pmthresholds.sts.nearend.1day.FC 40 (count) 0 - 6912
DS3.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400
DS3.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400