4023074 Rev B Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 4-49
Setup Menu: Outputs: TS Out
TS OUT
The Cueing submenus are not used in this release.
ASI
Name
Description: This is the name assigned to the transport output for ease of
reference.
Parameters: 20-character string.
Rate Control
Description: This is the DPM output rate control (in Mbps) when using an RF
input source.
Parameters: Auto or User. The table below describes the affect each of the
settings has on the output bit rate.
Rate Control Description
Auto The output rate follows that set by the
uplink. The output rate will be the same as
the input rate (including all null packets).
This means the output bit rate is determined
automatically based on the input source
symbol rate and FEC value.
User The output rate is specified as the Output
Rate parameter. It is determined by the user
setting regardless of the input source.