4-76 Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 4023074 Rev B
Setup Menu: Alarm/Warning, Continued
Rly - Yes or No. When set to Yes, the rear panel alarm relay will be
triggered to enable external equipment connected to the alarm port.
Trp - Yes or No. When set to Yes, the SNMP trap message will be
sent to the trap destination; otherwise the fault message will be
ignored.
“No*” indicates the trap or relay is enabled, but Enable is set to No,
which will prevent relay or trap operation.
System Warning Name
Description: Displays a list of the warning messages. You can scroll through the
list using the UP and DOWN arrow keys.
Parameters: Enable - Yes or No. When set to Yes, the warning message will be
reported. When set to No, the fault won’t be reported.
Note: Enable must be set to Yes for Relay and Trap messages
reporting to be functional.
Rly - Yes or No. When set to Yes, the rear panel alarm relay will be
triggered to enable external equipment connected to the alarm port.
Trp - Yes or No. When set to Yes, the SNMP trap message will be
sent to the trap destination; otherwise the warning message will be
ignored.
“No” indicates the trap or relay is enabled, but Enable is set to No,
which will prevent relay or trap operation.