Preparing the machine for use
Page 22 CM6200 Operating Manual
4. When unpacking the machine, place machine on 4" (102 mm) high blocks
to prevent damaging the components.
5. Use solvent to remove any protective coatings.
The machine ships from CLIMAX with a heavy coating of LPS 3. The recom-
mended cleaner is LPS PreSolve Orange Degreaser. During machine use, an alter-
nate long-term corrosion preventative may be used. Always use the correct cleaner
for the applied protective coating.
Contact CLIMAX immediately to report damaged or missing components.
3.2 PREPARING THE MACHINE FOR USE
3.2.1 Pre-setup check
The CM6200 can be set up and mounted in many ways. Before setting up the mill,
check the following:
• The machine assemblies are positioned correctly.
• There is enough room to position the entire machine on or near the
work piece.
• All connections are correctly attached.
3.2.2 Assessing the work area
The CM6200 often is used in dangerous locations (in elevated positions, near other
operating equipment, overhead, etc.). CLIMAX cannot foresee where this machine
will be used; therefore, you must perform a site-specific risk assessment
(Section 1.5 on page 4 and Section 1.6 on page 5) for each job before starting
work.
The CM6200 has remote operation features that enable you to choose the optimum
location to work from (Section 1.6 on page 5).
Always follow safe work practices, including site-specific safety
requirements. It is your responsibility to perform a risk assessment
before you set up the machine and each time before you operate the
machine.
3.3 LIFTING AND RIGGING
The CM6200 can weigh 10,000 lbs (4,536 kg) when fully assembled in
the ID configuration, and 12,000 lbs (5,456 kg) in the OD configuration.