This document contains proprietary information,
see proprietary statement on first page.
(4) With the Antennas connected to their corresponding radios, transmit with the
Communications analyzer to all receivers in each radio using an antenna that is
located 10-20 feet away from each C-5000 system antenna. Verify that the signal
is received with good audio quality.
8.3.C Encryption Verification
(1) If any of the transceiver modules use encryption, verify the ability to load
encryption keys. See the RT-7000 PMR/RMR Operator's manual for instructions
on how to set up the RT-7000 PMR to receive encryption keys (KVL Load).
(2) If the transceiver module is capable of performing an OTAR and the system is in
a location during checkout procedures where it can access an OTAR station, test
this function on all applicable transceivers.
These commodities, technology or software are controlled in accordance with the United States Export Administration Regulations, Export Classification
Control Number (ECCN) EAR99. When exporting, diversion contrary to U.S. law is prohibited.