4. Place the C-Mount cover on the front of the device, and tighten the screws.
Note:
Observing the tightening sequence below, tighten all six M2 x 12 mm Phillips Pan screws to 12 Ncm using a
torque wrench.
5. Place the lens cover adapter plate on the C-Mount cover, and tighten the screws.