DT-4500 Series C- and Ku-Band Down Converters MN/DT4500.IOM
Front Panel Operation Revision 2
6–10
6.2.3.2 (CONFIG:) REMOTE (Remote Control) Submenu
Remote Control: Local
SERIAL ETHERNET
Use the keys to select Local, SERIAL, or ETHERNET. Press ENTER.
6.2.3.2.1 (REMOTE:) Local
1) When you select Local mode, remote monitoring is possible, but
remote control is disabled.
2) A number of operations are possible in Local mode only. If you are
in Serial or Ethernet mode during such tasks, the unit alerts you to
this remote state:
Remote Mode: press ENTER
for local mode, or CLEAR
Press ENTER to switch to Local Mode to continue with your task, or
press CLEAR to exit the task and remain in the active mode.
6.2.3.2.2 (REMOTE:) SERIAL
Serial Mode = RS-232
Addr=001 Baud=9600 8-N-1
On the top line, use the  keys to set the mode to RS-232 or RS-485. Press
ENTER. On the bottom line, set the Serial address (Addr). Use the keys to
select a digit, and then use the  keys to change that digit. The valid range of
addresses is from 001 (default) to 255.
Next, set the Baud rate. Use the keys to select a parameter, and then use
the  keys to select your desired baud rate. Available choices are 1200, 2400,
4800, 9600 (default), 19K2, and 38K4.