DT-4500 Series C- and Ku-Band Down Converters MN/DT4500.IOM
Specifications Revision 2
2–2
2.1.3 Mean Time Between Failures (MTBF)
49,740 hrs as calculated
>100,000 hrs based on field experience
2.1.4 Temperature Range
Operating: 32° to 122° F (0° to 5C)
Storage: -4° to 158 F° (-20° to 70° C)
2.1.5 Humidity (Non-condensing)
Operating: 0 to 95% Relative maximum
Storage: 99% maximum
2.1.6 Altitude
10,000 ft Mean Sea Level (MSL)
2.1.7 Front Panel Features
2.1.7.1 Sample Test Point Connectors
STANDARD:
o (1X) ‘RF’ Type SMA’female, -20 dBc nominal
o (1X) ‘IF’ BNC female, -20 dBc nominal
OPTIONAL:
RF LO monitor available (0 dBm nominal replaces ‘RF’ sample point)
2.1.7.2 LED Monitoring
Six Status LEDs:
POWER ON (GREEN)
OUTPUT ENABLE (AMBER)
REMOTE (AMBER)
ON LINE (AMBER)

Table of Contents