EasyManua.ls Logo

Comtech EF Data DT-4500 Series - Conversion; Frequency Selection Step Size; Preset Channels; Stability over Time

Comtech EF Data DT-4500 Series
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DT-4500 Series C- and Ku-Band Down Converters MN/DT4500.IOM
Specifications Revision 2
2–7
• DT-4510/D: 10.70 to 11.70 GHz
• DT-4511: 11.70 to 12.20 GHz
• DT-4512: 12.20 to 12.75 GHz
• DT-4512/E: 12.50 to 12.80 GHz
• DT-4513: 10.95 to 12.75 GHz
• DT-4513/E: 10.70 to 12.75 GHz
2.2.2 Conversion
Dual, no inversion.
2.2.3 Frequency Selection Step Size
• STANDARD: 125 kHz steps
• OPTIONAL: 1 kHz steps
2.2.4 Preset Channels
32 frequencies and gains
2.2.5 Stability Over Time
± 1 x 10
-9
/day
2.2.6 Stability Over Temperature
± 1 x 10
-8
32° to 122°F (0° to 50°C)
2.2.7 RF Input
2.2.7.1 Input Level
-45 dBm typical

Table of Contents