DT-4500 Series C- and Ku-Band Down Converters MN/DT4500.IOM
Serial Interface Operation Revision 2
8–11
8.7.1.5 Stored Alarm Queries Quick Reference
Return Total Stored Alarms
8.7.2 Utility Commands/Queries
8.7.2.1 TIM (Time)
Use TIM to set or return the time.
<DEV/TIM_hh:mm:ss{cr} where:
hh=Hour
mm=Minutes
ss=Seconds
>DEV/TIM_hh:mm:ss{cr}{lf}]
>DEV/TIM_hh:mm:ss{cr}{lf}]
8.7.2.2 DAT (Date)
Use DAT to set or return the date.
<DEV/DAT_mm/dd/yy{cr} where:
mm=Month
dd=Day
>DEV/DAT_mm/dd/yy{cr}{lf}]
>DEV/DAT_mm/dd/yy{cr}{lf}]