DT-4500 Series C- and Ku-Band Down Converters MN/DT4500.IOM
Serial Interface Operation Revision 2
8–18
8.7.2.21 FRM (Firmware Information)
Use FRM to query the firmware loaded in the current production unit. This
includes firmware numbers, versions, and release dates. This query replaces the
legacy FRW query.
Return Firmware Information:
Boot: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk1: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk2: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}{lf}]
where: FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
8.7.2.22 IMG (Firmware Image)
Use IMG to set or return selection of a valid bulk image as the next active boot
image.
<DEV/IMG_x{cr} where:
x = 1 or 2