Product Manual Doc. 9349B Crestron Zūm® Wired Solutions 75
NET
(24 Y Z G)
(1) 4-pin 3.5mm detachable terminal block;
Connects to a GLS-SIM which facilitate Demand Response when connected to
a nonsystem sensor, such as a GLS-ODT-C-NS;
Not used for power
24VDC 2.0A (1) 2.1 x 5.5mm DC power connector;
24VDC power input;
PW-2420RU power pack included
G (1) 6-32 screw;
Chassis ground lug
COMPUTER
(front)
(1) USB Type B connector, female;
USB 2.0 device port for configuration via computer console (cable included)
Controls & Indicators
PWR (1) Green LED;
Indicates operating power supplied from the included power pack
NET (1) Amber LED;
Not used
MSG (1) Red LED;
Indicates that the ZUM-HUB4 has generated an error message
HW-R (1) Recessed pushbutton for hardware reset
SW-R (1) Recessed pushbutton for software reset
LAN (rear) (2) Bi-color green/amber LEDs;
Left LED indicates Ethernet link status and connection speed;
Right LED indicates Ethernet activity
CONTROL SUBNET
(rear)
(2) Bi-color green/amber LEDs;
Left LED indicates Ethernet link status and connection speed;
Right LED indicates Ethernet activity
Power
Power Pack (included) Input: 100–240VAC, 50/60Hz;
Output: 2.5A @ 24VDC
Model: PW-2420RU
Power Consumption 15 W
Environmental
Temperature 41° to 113°F (5° to 45°C)
Humidity 10% to 90% RH (noncondensing)
Heat Dissipation 50 BTU/hr
Enclosure
Chassis Metal, black finish
Faceplate Extruded metal, black finish, polycarbonate label overlay
Mounting Freestanding or 1 RU 19-inch rack-mountable;
Adhesive feet and rack ears included