4.2.2 Example – connection and configuration of FRO and SRO potentiometers
Below you can see example of connection and configuration of potentiometers for feed rate correction
and spindle revs regulation.
As you can see in the scheme, 10V placed on the analog con-
nector is very convenient and useful - thanks to it we do not
need any external power supply for the potentiometers. The
Potentiometer 1was connected to the analog input no. 0, and
potentiometer 2 to analog input no 1. After the connection you
can check it by viewing analog inputs in the diagnostic window
– menu „PlugIn ControlCSMIO_IP plugin”, „Analog IO” tab.
If values on the analog inputs change with the position of the potentiometers' knobs, then only what left is
to configure the plugin. Open configuration window–
menu „ConfigConfigPlugInsCONFIG”. Choose
„OverrideSrc.”.
Select „CSMIO-IP AIN 0” for „Feedrateoverride” – so for
feed rate regulation we use POT.1 potentiometer.
For „Spindlespeedoverride” select „CSMIO-IP AIN 1”, so
for spindle revs regulation we use POT.2 potentiometer.
At the end click „Save” to keep this settings.
CS- Lab s.c. – CSMIO/IP- A - CNC controller
Page 17