4.11 Recommended cables
Connections type Recommended cable
Digital In/out Minimum cross-section 0,25mm
2
(AWG-23)
Analog In/out
Cross-section 0,25mm
2
(AWG-23)- shielded or pair of signal-to-
mass wires twisted together along the entire length
Encoder signals Cross-section 0,25mm
2
(AWG-23) - shielded - twisted. Eventual-
ly PC FTP cable. You should remember that for pair of signals
(e.g. A+/A-) always use twisted pair of cables.
Drives control
analog signals +/-10V
Cross-section 0,25mm
2
(AWG-23) - shielded - twisted. Eventual-
ly PC FTP cable. You should remember that for pair of signals
(e.g. Out Analog Ch0 /GND Ch0) always use twisted pair of ca-
bles.
Ethernet communication wire Standard network cable, shielded - FTP, cat. 6.
Power supply Min. cross-over 0,5mm
2
(AWG-20)
CAN expansion modules If modules are installed on the same DIN rail, right next to the
controller, you can use DB9 plugs clamped on a 9 wire tape. If
module is installed farther then you should use so-called
shielded twisted pair. (FTP or STP).
During mechanical and electrical montage particular caution is advised. Poorly tightened cable
may cause many troubles, it is also very difficult to find such a defect during launching/using the
system.
CS- Lab s.c. CSMIO/IP- A - CNC controller
Page 32

Table of Contents

Other manuals for CS-Lab CSMIO/IP-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CS-Lab CSMIO/IP-A and is the answer not in the manual?

CS-Lab CSMIO/IP-A Specifications

General IconGeneral
BrandCS-Lab
ModelCSMIO/IP-A
CategoryController
LanguageEnglish

Related product manuals