EasyManua.ls Logo

Daikin Super Multi Plus E-Series - Page 442

Daikin Super Multi Plus E-Series
456 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring Diagrams SiEN18-622
430 Appendix
2.3.5 Ceiling Mounted Cassette Type
FFQ25/35/50/60B8V1B
TO OUTDOOR UNIT
1.
C1
A3P
A4P
S1L
X1M
X2M
Q1M
R1T
SS1
R3T
R2T
R1T
F1U
HAP
A1P
M1F
M1P
M1S
V1TR
T1R
KPR
TC
RC
X2M
2
3
1
SIGNAL RECEIVER CIRCUIT
TERMINAL STRIP
TERMINAL STRIP
X2M
3
2
1
X24A
,
A1P
H05VV-U4G2.5
A3P
BS1
SS1
SS2
X40A
X60A
X61A
X33A
X35A
X2A
H1P
H2P
H3P
H4P
SS2
SS1
X1A
X2M
3
2
1
A4P
X1A
GRN/YLW
WHT
BLK
RED
H2P
H3P
H4P
H1P
BS1
F1U
X27A
X40A
X60A
X61A
RC
X19A
R1T
TC
X18A
R2T
X25A
KPR
X10A
X17A
R3T
YLW
YLW
WHT
YLW
YLW
X33A
T1R
M1P
~
M
X11A
X35A
HAP
V1TR
X24A
X1M
X36A
X15A
A1P
X20A
X5A
BLK
RED
3D038357B
A1P
X1M
F2
P2
F1
P1
GRN
YLW
C1
WHT
NE
X2M
S1L
T1R
SS1
P2
MSW
P1
M1S
M1F
C1
~
M
R1T
Q1M
IN CASE OF SIMULTANEOUS
OPERATION SYSTEM
INDOOR UNIT
(MASTER)
INDOOR UNIT
(SLAVE)
REMOTE
CONTROL
TO OUTDOOR
UNIT
NOTE 3
NOTES
:
TERMINAL
:
FIELD WIRING
:
CONNECTOR
RECEIVER/DISPLAY UNIT
2.
IN CASE USING CENTRAL REMOTE CONTROL, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED
INSTALLATION MANUAL.
3.
X24A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROL KIT IS BEING USED.
4.
REMOTE CONTROL MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM,
CONFIRM ENGINEERING MATERIALS AND CATALOGS, ETC. BEFORE CONNECTING.
5.
GROUND THE SHIELD OF THE REMOTE CONTROL CORD TO THE INDOOR UNIT(IN CASE OF USING SHIELD WIRE).
6.
SYMBOLSSHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW PRP: PURPLE GRY: GRAY BLU: BLUE
: CONNECTOR DISCRIMINATION COLOUR FOR COMPONENTS.
: CONNECTOR COLOUR FOR COMPONENTS.
: CONNECTOR COLOUR FOR PRINTED CIRCUIT BOARD.
WIRED
REMOTE
CONTROL
NOTE 3
NOTE 5
CONTROL BOX
PRINTED CIRCUIT BOARD
CAPACITOR(M1F)
FUSE(F5A 250V)
LIGHT EMITTING DIODE
(SERVICE MONITOR GREEN)
MAGNETIC RELAY(M1P)
MOTOR (INDOOR FAN)
MOTOR (DRAIN PUMP)
MOTOR (SWING FLAP)
THERMO SWITCH (M1F EMBEDDED)
THERMISTOR(AIR)
THERMISTOR (COIL-1)
THERMISTOR (COIL-2)
FLOAT SWITCH
TRANSFORMER(220-240V/22V)
PHASE CONTROL CIRCUIT
SIGNAL TRANSMISSION CIRCUIT
WIRED REMOTE CONTROL
THERMISTOR (AIR)
SELECTOR SWITCH (MAIN/SUB)
INFRARED REMOTE CONTROL
(RECEIVER/DISPLAY UNIT)
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
PUSH BUTTON (ON/OFF)
LIGHT EMITTING DIODE
(ON-RED)
LIGHT EMITTING DIODE
(TIMER-GREEN)
LIGHT EMITTING DIODE
(FILTER SIGN-RED)
LIGHT EMITTING DIODE
(DEFROST-ORANGE)
SELECTOR SWITCH
(MAIN/SUB)
SELECTOR SWITCH
(WIRELESS ADDRESS SET)
CONNECTOR FOR OPTIONAL PARTS
CONNECTOR
(ADAPTER FOR WIRING)
CONNECTOR
(GROUP CONTROL ADAPTER)
CONNECTOR
(ON/OFF INPUT FROM OUTSIDE)
CONNECTOR
(INTERFACE ADAPTER
FOR SKYAIR SERIES)

Table of Contents

Related product manuals