Technical Specifications
32
Arex™ 400
Device Port 1
Control rack back panel connector
Plug, M12, 8 positions male.
Figure 14: Device Port 1 connector, male panel plug (front view)
PIN SIGNAL TYPE (*) DESCRIPTION
1 VCC Power Output Auxiliary 24V DC power supply (15W max power)
2 GND Ground Ground reference
3 EXT_TRIG_#1 Digital Output
Reserved output for MARVIS™
4 EXT_INPUT_#1 Digital Input Reserved input for MARVIS™
5 RESERVED -
DO NOT CONNECT
6 INT_RS232_RX Digital Input Reserved RS232 for micrometric distance sensor
7 INT_RS232_TX Digital Output
Reserved RS232 for micrometric distance sensor
8 RESERVED - DO NOT CONNECT
BODY SHIELD Shield Connector case provides
electrical connection to the body
Table 6: Device Port 1 connector pinout
(*) see “Input/Output specifications” on page 34
Device Port 2
Control rack back panel connector
Plug, M12, 8 positions male.
Figure 15: Device Port 2 connector, male panel plug (front view)
PIN SIGNAL TYPE (*) DESCRIPTION
1 VCC Power Output Auxiliary 24V DC power supply (15W max power)
2 GND Ground Ground reference
3 EXT_TRIG_#2 Digital Output
Reserved output for MARVIS™
4 EXT_INPUT_#2 Digital Input Reserved input for MARVIS™
5 RESERVED -
DO NOT CONNECT
6 RESERVED - DO NOT CONNECT
7 RESERVED -
DO NOT CONNECT
8 RESERVED - DO NOT CONNECT
BODY SHIELD Shield Connector case provides
electrical connection to the body
Table 7: Device Port 2 connector pinout
(*) see “Input/Output specifications” on page 34