Technical Specifications
34
Arex™ 400
Input/Output specifications
Digital Input
USING EXTERNAL POWER SUPPLY
USING AUXILIARY POWER SUPPLY
USER SIDE
USER SIDE
LASER MARKER SIDE
LASER MARKER SIDE
TECHNICAL CHARACTERISTICS
Type
Optocoupler
Vmax
28 V DC
Imax
10 mA @ 24 V DC
Pulse Width
1ms (debounce)
MIN TYP
MAX
INPUT Logic LOW
0.0 V DC 0.0 V DC 2.0 V DC
INPUT Logic HIGH
10.0 V DC 24.0 V DC 28.0 V DC
Table 9: Digital Input specification
Digital Output
USING EXTERNAL POWER SUPPLY
USING AUXILIARY POWER SUPPLY
USER SIDE
USER SIDE
LASER MARKER SIDE
LASER MARKER SIDE
TECHNICAL CHARACTERISTICS
Type Low side driver
Vmax 24 V DC
Imax
250 mA
LOW Level Output V 0.5 V DC; I 250mA
HIGH Level Output V
24 V DC; I 5μA
Table 10: Digital Output specification