Laser Marker States
User Manual 35
Laser Marker States
Normal Operation States
STATE DESCRIPTION STATUS LED
SYSTEM BOOTING UP
This state occurs since the laser marker
is switched on until Laser
Engine has been loaded and no errors occurred
Blinking
WAIT FOR START
In this state the laser marker cannot emit IR lasers radiation and Aiming
and Focus beam cannot be activated
Steady
STANDBY SHUTTER CLOSED
In this state Aiming and Focus beam can be activated while the laser
marker cannot
emit IR laser radiation
Steady
READY In this state the laser marker is able to emit IR laser radiation
Steady
Error States
STATE DESCRIPTION STATUS LED
ERROR
This state occurs if the laser marker detects an error that prevents nor-
mal operation
Blinking
SYSTEM ERRORS DESCRIPTION
INTERLOCK ERROR
This error rise if the INTERLOCK function is ON. To reset the error, set INTERLOCK function
to OFF and repeat the turning on sequence
CBOX ERROR
This error rise if the
CONNECTOR_PRESENCE
signal (pin 10 Command Box connector) is
LOW or not connected. To reset the error, set
CONNECTOR_PRESENCE
signal to HIGH value
and repeat the turning on sequence
RACK TEMPERATURE ERROR
This error rise if the temperature inside the control rack is out of the operating tempera-
ture range. To reset the error, a Laser marker restart is required
SCANHEAD TEMPERATURE
ERROR
This error rise if the temperature inside the scan head is out of the operating temperature
range. To reset the error, a Laser marker restart is required
SCANHEAD CONNECTION
ER
ROR
This alarm rise if the cable between control rack and scan head is not connected. To reset
the error, a Laser marker restart is required
LASER SOURCE ERRORS DESCRIPTION
TEMPERATURE ERROR
This error rise if the temperature inside the laser source is out of the operating tempera-
ture range. To reset the error, a Laser marker restart is required
POWER SUPPLY ERROR
This error rise if the power supply of the laser source is out of range. To reset the error, a
Laser marker restart is required
BACK REFLECTION ERROR
This error rise if high optical power is reflected back to the laser source. To reset the error, a
Laser marker restart is required
GENERIC ERROR
This error rise if the laser source detects an internal failure. To reset the error, a Laser
marker restart is required
Warning State
STATE DESCRIPTION STATUS LED
WARNING INVALID START
SEQUENCE
This state occurs if the turning on sequence has not been followed. To
restore normal laser marker operation, repeat the turning on sequence
Blinking