EasyManua.ls Logo

Datalogic Arex 400 - Air Filter Cleaning Procedure

Datalogic Arex 400
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
User Manual 75
Air filter cleaning procedure
Procedure:
Turn off key switch on controller unit
Disconnect AC power cable
Untight grid panel screws and remove it
Remove filter
Figure 2: Removal of air filter
Clean filter with compressed air or with neutral detergent and air-dry it
Reinstall filter and grid pane
W
ARNING
W
ARNING
DO NOT install wet filter!
Insert the filter making sure that the surface with the wider meshes is oriented
towards the outside.
If filter cannot be cleaned, replace the filter
Suitable filters are available as spare parts