Enter/Exit Programming Mode MSI
122 Magellan™ 3200VSI
MSI Length Control
Specifies either variable-length decoding or fixed-length decoding for MSI.
Fixed Length Decoding — When fixed length decoding is enabled, the scanner
will decode a bar code if the label length matches one of the configurable fixed
lengths.
Variable Length Decoding — When variable length decoding is enabled, the scan-
ner will decode a bar code if the label length falls in the range of the configu-
rable Length 1 and Length 2 values.
Variable Length Decoding
DEFAULT
Fixed Length Decoding
MSI Length 1, Length 2 Programming Instructions
1. See Length 1, Length 2 Programming Instructions on page 148 for detailed
instructions on setting this feature
.
NOTE
DEFAULT SETTING FOR THIS FEATURE: 04
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 10
For MSI bar codes, length includes the barcode's check and data characters.