EasyManua.ls Logo

Datalogic MAGELLAN 3200VSI - Length Control; Configuring Variable Length Decoding

Datalogic MAGELLAN 3200VSI
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Reference Guide
147
Figure 4. Label ID Position
OR
Prefix SuffixLabel ID Label IDBar Code DataAim ID
Options
Length Control
Fixed Length Decoding — When fixed length decoding is enabled, the scanner
will decode a bar code if the label length matches one of the configurable fixed
lengths.
Variable Length Decoding — When variable length decoding is enabled, the scan-
ner will decode a bar code if the label length falls in the range of the configu-
rable minimum and maximum le
ngth.
Configuring Fixed Length Decoding:
1. Scan the Enter/Exit Progr
amming Mode bar code.
2. Scan the Fixed Length Decoding bar code for the
desired symbology.
3. Scan the Enter/Exit Progr
amming Mode bar code.
4. Set Length 1 to the first fixed leng
th by following the Length 1, Length 2
Programming Instructions below.
5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed
le
ngth) by following the Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the Variable Length Decoding
bar code for the desired symbology.
3. Scan the Enter/Exit Progr
amming Mode bar code.
4. Set Length 1 to the first varia
ble length by following the Length 1, Length
2 Programming Instructions below.
5. Set Length 2 to the second variable length by following the Length 1,
Length 2 Programming Instructions below.