EasyManua.ls Logo

Datalogic MAGELLAN 3200VSI - QR Code Length Control; Configuring Variable Length Decoding

Datalogic MAGELLAN 3200VSI
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode QR Code
134 Magellan™ 3200VSI
QR Code Length Control
Fixed Length Decoding — When fixed length decoding is enabled, the scanner
will decode a bar code if the label length matches one of the configurable fixed
lengths.
Variable Length Decoding — When variable length decoding is enabled, the scan-
ner will decode a bar code if the label length falls in the range of the configu-
rable Length 1 and Length 2 values.
Configuring Fixed Length Decoding:
1. Scan the Enter/Exit Programming
Mode bar code.
2. Scan the Fixed Length
Decoding bar code.
3. Complete the programming sequence by
scanning the Enter/Exit Pro-
gramming Mode bar code.
4. Set Length 1 to the first fixed length
by following the Length 1, Length 2
Programming Instructions below.
5. Set Length 2 to the second fixed length (or t
o ‘0000’ if there is only one
fixed length) by following the QR Code Length 1, Le
ngth 2 Programming
Instructions below.
Configuring Variable Length Decoding:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the Variable Length Decoding
bar code.
3. Complete the programming sequence by
scanning the Enter/Exit Pro-
gramming Mode bar code.
4. Set Length 1 to the minimum length by following the QR Code Length 1,
Length 2 Programming Instructions below.
5. Set Length 2 to the maximum
length by following the QR Code Length 1,
Length 2 Programming Instructions below.
Variable Length Decoding
DEFAULT
Fixed Length Decoding