EasyManua.ls Logo

Datalogic MAGELLAN 3200VSI - Physical Properties; Electrical Parameters; Environmental Parameters; Other Parameters

Datalogic MAGELLAN 3200VSI
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150 Magellan™ 3200VSI
Physical Properties
Parameter Specification
Dimensions (Scanner only): 6” x 5.6” x 3.3” (WxHxD)
Weight (Scanner) 1 lb 4.6 oz (0.584kg)
Electrical Parameters
Parameters Specification
AC Power Requirements AC Input: 90-264 VAC, 47~63Hz
AC Power Consumption
Real Power
Operating (Maximum)
8.75Watts
Operating (Nominal)
2.8Watts
Sleep mode
2.0Watts
DC Power Requirements Reference for POT user
Input Voltage
7 to 14 V DC
Operating Current and Power at 12V
DC
Current Power
Maximum Inrush
715mA 8.6 Watts
Maximum Continuous
545mA 6.6 Watts
Nominal Scanner Only
180mA 2.2 Watts
Sleep, Scanner Only
123mA 1.5 Watts
Environmental Parameters
Parameter Specification
Contaminants
Water and Dust
IP5x
Temperature Ranges:
Operating
32
F to +104
F (0
C to +40
C)
Storage
-40
F to +158
F (-40
C to +70

C)
Ambient Light Indoor
0 - 6,000 lux
Ambient Light Outdoor
0 - 86,100 lux
Humidity
5% to 95% non-condensing
Beeper/Speaker
70-90dBA at a distance of 3’-3” (1 meter)
Vibration
Retail/Office
Other Parameters
Parameter Specification
EAS Support
YES (Checkpoint)

Table of Contents

Other manuals for Datalogic MAGELLAN 3200VSI