Enter/Exit Programming Mode
62 Magellan™ 3200VSI
Single Cable RS-232 Use ETX
Enables/disables the ability of the scanner to use ETX.
Disable ETX
Enable ETX
DEFAULT
Set Single Cable RS-232 ETX Character
Allows selection of the ETX character.
To specify the ETX Character:
1. Scan the Enter/Exit Programming
Mode bar code.
2. Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below.
Yo
u’ll need to cover any unused bar codes on this and the facing page to
ensure the scanner reads only the bar code you intend to scan.
3. Scan the appropriate characters/digits from the keypad in Appendix that
represent the decimal designation for the desired character. A table con-
taining the ASCII Char
acter Set and their corresponding decimal values is
available in the inside back cover of this manual. ASCII parameters must be
input by scanning decimal digits for each character. Pad all numbers with
leading zeroes to yield a three-digit entry (001-127). Thus, to set a single
character value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must
be scanned. The selectable range for this option is any decimal value from
001 to 127.
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits
have been scanned.
SET SINGLE CABLE RS-232 ETX CHARACTER