Enter/Exit Programming Mode Composite Labels
142 Magellan™ 3200VSI
Composite Labels
Disable/Enable GS1 DataBar Omnidirectional 2D Component
When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the
2D linkage flag set, the 2D component must also be decoded or the base label
will be discarded.
When disabled, only the GS1 DataBar Om
nidirectional base label will be
decoded and transmitted regardless of the state of the linkage flag.
Disable GS1 DataBar Omnidirectional 2D Component
DEFAULT
Enable GS1 DataBar Omnidirectional 2D Component
Disable/Enable GS1 DataBar Expanded 2D Component
When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D
linkage flag set, the 2D component must also be decoded or the base label will
be discarded.
When disabled, only the GS1 DataBar Expanded base
label will be decoded and
transmitted regardless of the state of the linkage flag.
Disable GS1 DataBar Expanded 2D Component
DEFAULT
Enable GS1 DataBar Expanded 2D Component