RF Programming Manual 85
QuadraLogic
™ II
Decoding
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for Code 39/PharmaCode 39 symbologies.
PharmaCode
39 Options
PharmaCode 39 symbology has the following programmable features:
Transmit Check Digit
Start/Stop Characters
Transmit
Check Digit
Transmit Check Digit selects whether the Check Digit will/won’t be
transmitted to the host terminal.
Start/Stop
Characters
Start/Stop Characters directs the scanner to either Send or Don’t Send
depending on your host’s interface requirement.
SET ------------------------------------------
Activate for Code 39/
PharmaCode 39 ---------
Deactivate for Code 39/
PharmaCode 39 ---------
END ------------------------------------------
NOTE
In order for PharmaCode 39 labels to be read
and transmitted as PharmaCode 39, the Code
39 symbology must first be enabled.