Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 63
(BZ) Buzzer Enable – This command controls the audible signaling device that
acknowledges User Interface entries and, if enabled, sounds printer warning and
fault conditions.
(CA) Column AdjustThis command fine-tunes the Column Offset setting by
shifting both the horizontal start of print position and the Label Width termination
point to the right in dots (see Appendix K) to compensate for slight mechanical
differences sometimes evident when multiple printers share label formats. Note that
the EX2 accepts this command for backward compatibility only, limited in range (28-
228). The <STX>KcQQQ response will show the Column Adjust Fine Tune (CF)
equivalent value.
(CB) Cut Behind – This command allows the printer to queue a specified number of
small labels before a cut is performed to increase throughput.
(CC) Control Codes – This command, depending upon printer type, allows a
change to the prefix of the software commands interpreted by the printer:
Value
Units /
Interpretation
Control Code Definition
S Standard Codes
Hex 01 = SOH command; Hex 02 = STX command; count-
by = ^; Hex 1B = ESC; Hex 0x0D = Carriage Return
1 Alternate Codes
Hex 5E = SOH command; Hex 7E = STX command; count-
by = @; Hex 1B = ESC; Hex 0x0D = Carriage Return
2 Alternate Codes 2
Hex 5E = SOH command; Hex 7E = STX command; count-
by = @; Hex 1B = ESC; Hex 0x7C = Carriage Return
(CE) Cutter Equipped – This command allows the printer to sense the cutter option.
“A” - automatically senses device presence; if undetected, no error is generated. “E” -
enables the device, where its presence must be detected; otherwise, a fault is
generated. “N” - disables device detection. One of these values is returned in
response to <STX>KcQQQ. Note that alternate values are accepted for backward
compatibility as follows: For display-equipped models “Y” is equivalent to “A”; and,
for non-display models “Y” is equivalent to “E”.
(CF) Column Adjust Fine TuneThis command fine-tunes the Column Offset
setting by shifting both the horizontal start of print position and the Label Width
termination point to the right in dots (see Appendix K) to compensate for slight
mechanical differences sometimes evident when multiple printers share label
formats.

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz