Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 103
STX Kd Set File as Factory Default
This command selects the specified file name as the “factory default” configuration. After
execution, subsequent “Select Factory Default” commands will configure the printer to
this file’s configuration using one of the following methods:
<STX>KF command;
Power-up the printer while pressing the PAUSE and CANCEL Keys; or,
Via the menu SYSTEM SETTINGS / SET FACTORY DEFAULTS entry.
Syntax:
<STX>KdName<CR>
Name
-
The name, up to 16 characters, of the file.
Where:
<CR>
-
0x0d terminates the name.
Sample:
<STX>KdPlant1<CR>
The sample above selects the configuration file Plant1 as the
default factory configuration.
STX KE Character Encoding
This command is provided primarily as a means for users of 7-bit communication and to
embed control characters and extended ASCII characters in their data streams. Any
character in the DPL data stream may be substituted with a delimited two-character
ASCII hexadecimal numeric equivalent. The command allows the delimiting character to
be selected, and the encoding to be enabled or disabled. When character encoding is
enabled, the printer will decode any ASCII hexadecimal numeric pairs following the
delimiter as single-byte values. Character encoding is used where control characters
cannot be transmitted or where control characters within data may prematurely
terminate a label format record. Although the delimiter may be changed at any time
(except within a label format definition), there cannot be more than one defined
delimiter, and character encoding must be disabled with <STX>KEN prior to re-enabling
regardless of any change in the delimiter.
Syntax:
<STX>KEex<CR>
e
-
Y
character encoding enabled
Ncharacter encoding disabled
Where:
x
- Delimiter: one ASCII character (Do not include when e = N)
Sample:
<STX>KEN
<STX>KEY\
<STX>L<CR>
1u0000001200120[)>\1E\01\1D\...\04\<CR>
E<CR>

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz

Related product manuals