Class Series 2 Programmer’s Manual 17
4
System-Level Command Functions
Introduction
The most commonly used commands are the System-Level Commands. These are used to
load and store graphics information, in addition to printer control. System-Level Commands
are used to override default parameter values (fixed and selectable) and may be used
before or after Immediate Commands but cannot be issued among Label Formatting
Commands. System-Level Commands consist of:
1. Attention-Getter, 0x02 or 0x7E; see Control Code Command Functions.
2. Command Character
3. Parameters (if any).
STX A Set Time and Date
This command sets the time and date. The initial setting of the date will be stored in the
printer’s internal inch counter. This date can be verified by printing a Configuration
Label.
Syntax:
<STX>AwmmddyyyyhhMMjjj
Where:
w
1 digit for day of week; 1 = Monday; 7 = Sunday
mm
2 digits for month
dd
2 digits for day
yyyy
4 digits for year
hh
2 digits for hour in 24 hour format
MM
2 digits for minutes
jjj
3 digits for Julian date / constant; see notes below.
Sample:
<STX>A1020319960855034
Printed response:
Mon. Feb 3, 1996, 8:55AM, 034
When set to 000, the Julian date is automatically calculated; otherwise, the Julian
date will print as entered, without daily increments. If factory defaults are restored
the actual Julian date will also be restored.
Printers without the Real Time Clock option lose the set time/date when power is
removed.
Response format is variable; see the Special Label Formatting Command <STX>T.

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz