Extended System-Level Command Functions
110 Class Series 2 Programmer’s Manual
STX Kp Module Protection
This command controls memory module protection. When “protected”, a module will
ignore format, downloads and delete commands. This command can be useful to add
data to reserved modules (see Appendix K for a listing of the memory modules). There
are two module types: RAM (volatile) and Flash (non-volatile).
RAM - When protected and if power is cycled or if the printer is reset, the module
state resets to unprotected.
Flash - When protected, the module can be temporarily unprotected; however, if
power is cycled or if the printer is reset, the module state resets to protected.
Syntax:
<STX>Kpmf
m
-
Module ID – Range A to Z (See Appendix K).
Where:
f
-
Flag specifying Enable or Disable protection, where:
0 = disable protection; and,
1 = enable protection.
Sample:
<STX>KpY0
The sample above disables protection for Module Y; graphics may
now be downloaded to the module and, on subsequent resets,
these graphics will be protected.