Chapter 4 Installation
PAGE 4-17
BUSY: SIGNAL DURING FASTENING PIN No.: TB2-5 OUT-5
The “ON” output is performed when the Unit is performing the fastening process.
MANREV / RELAY CONTACT-1 SIGNAL PIN No.: TB2-7 OUT-8
RELAY CONTACT –COM SIGNAL PIN No.: TB2-10
Turns ON by manually starting the reversed operation.
Turns OFF when the next fastening starts, or turns “OFF” at RESET, PROGRAM.
For details, refer to PAGE4-5-5. [MANREV signal timing chart].
This signal can be used with controller software version V1.007 or later.
BUZZER / RELAY CONTACT-2 SIGNAL PIN No.: TB2-8 OUT-9
RELAY CONTACT –COM SIGNAL PIN No.: TB2-10
Performs interlocking output of REJECT signal ON/OFF to external devices.
Turns ON while the output signal [REJECT] is ON.
Turns ON for 0.4 seconds by the output signal [BATCH OK] rise-up.
Turns ON for 0.1 seconds by the output signal []QL OK] rise-up.
Click sound of the operation switch is not output.