EasyManuals Logo

Digi XBee SX User Manual

Digi XBee SX
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
AT commands I/O line passing commands
XBee®/XBee-PRO SX RF Module User Guide
100
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T2 (D2 Output Timeout)
Specifies how long pin D2 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T3 (D3 Output Timeout)
Specifies how long pin D3 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T4 (D4 Output Timeout)
Specifies how long pin D4 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T5 (D5 Output Timeout)
Specifies how long pin D5 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee SX and is the answer not in the manual?

Digi XBee SX Specifications

General IconGeneral
BrandDigi
ModelXBee SX
CategoryControl Unit
LanguageEnglish

Related product manuals