AT commands I/O line passing commands
XBee®/XBee-PRO SX RF Module User Guide
101
T6 (D6 Output Timeout)
Specifies how long pin D6 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T7 (D7 Output Timeout)
Specifies how long pin D7 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T8 (D8 Timeout)
Specifies how long pin D8 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T9 (D9 Timeout)
Specifies how long pin D9 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q0 (P0 Timeout)
Specifies how long pin P0 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)