AT commands Command mode options
XBee®/XBee-PRO SX RF Module User Guide
107
OS (Operating Sleep Time)
Reads the current network sleep time that the device is synchronized to, in units of 10 milliseconds. If
the device has not been synchronized, then OS returns the value of SP.
If the device synchronizes with a sleeping router network, OS may differ from SP.
Parameter range
N/A
Default
N/A
OW (Operating Wake Time)
Reads the current network wake time that a device is synchronized to, in 1 ms units.
If the device has not been synchronized, then OW returns the value of ST.
If the device synchronizes with a sleeping router network, OW may differ from ST.
Parameter range
N/A
Default
N/A
MS (Missed Sync Messages)
Reads the number of sleep or wake cycles since the device received a sync message.
Parameter range
N/A
Default
N/A
SQ (Missed Sleep Sync Count)
Counts the number of sleep cycles in which the device does not receive a sleep sync.
Set the value to 0 to reset this value.
When the value reaches 0xFFFF it does not increment anymore.
Parameter range
0 - 0xFFFF
Default
N/A
Command mode options
The following commands are Command mode option commands.