EasyManuals Logo

Digi XBee SX User Manual

Digi XBee SX
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
AT commands Diagnostic - addressing commands
XBee®/XBee-PRO SX RF Module User Guide
77
Bit field
Option Description
0x01
Append the DD (Digi Device Identifier) value to ND responses or API node identification
frames.
0x02
Local device sends ND response frame out the serial interface when ND is issued.
0x04
Append the RSSI of the last hop to ND, FN, and responses or API node identification
frames.
Default
0x0
CI (Cluster ID)
The application layer cluster ID value. The device uses this value as the cluster ID for all data
transmissions.
If you set this value to 0x12 (loopback Cluster ID), the destination node echoes any transmitted
packet back to the source device.
Supported Cluster IDs
0x11: Transparent data (default)
0x12: Loopback
0x14: Test Link Request
0x94: Test Link Result
0x23: Memory Access (GPM)
Parameter range
0 - 0xFFFF
Default
0x11 (Transparent data cluster ID)
Diagnostic - addressing commands
The following AT command is a Diagnostic - addressing command.
N? (Network Discovery Timeout)
The maximum response time, in milliseconds, for ND (Network Discovery) responses and DN (Discover
Node) responses. The timeout is based on the NT (Network Discovery Back-off Time) and the network
propagation time.
Parameter range
[read-only]
Default
N/A