AT commands I/O settings commands
XBee®/XBee-PRO SX RF Module User Guide
85
Parameter Description
0 Disabled
0 Unmonitored digital input
1 Commissioning Pushbutton
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
Default
1
D1 (DIO1/AD1)
Sets or displays the DIO1/AD1 configuration (pin 32).
Parameter range
0, 2 - 5
Parameter Description
0 Disabled
1 N/A
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
6 PTI_EN
Default
0
D2 (DIO2/AD2)
Sets or displays the DIO2/AD2 configuration (pin 31).
Parameter range
0, 2 - 5