AT commands Security commands
XBee®/XBee-PRO SX RF Module User Guide
80
NI<CR> (Variable length)
PARENT_NETWORK ADDRESS<CR> (2 Bytes) (always 0xFFFE)
DEVICE_TYPE<CR> (1 Byte: 0 = Coordinator, 1 = Router, 2 = End Device)
STATUS<CR> (1 Byte: Reserved)
PROFILE_ID<CR> (2 Bytes)
MANUFACTURER_ID<CR> (2 Bytes)
DIGI DEVICE TYPE<CR> (4 Bytes. Optionally included based on NO settings.)
RSSI OF LAST HOP<CR> (1 Byte. Optionally included based on NO settings.)
<CR>
If you send the FN command in Command mode, after (NT*100) ms + overhead time, the command
ends by returning a carriage return, represented by <CR>.
If you send the FN command through a local AT Command (0x08) or remote AT command (0x17) API
frame, each response returns as a separate AT Command Response (0x88) or Remote Command
Response (0x97) frame, respectively. The data consists of the bytes in the previous list without the
carriage return delimiters. The NI string ends in a 0x00 null character.
Parameter range
N/A
Default
N/A
Security commands
The following AT commands are security commands.
EE (Encryption Enable)
Enable or disable 256-bit Advanced Encryption Standard (AES) encryption.
Set this command parameter the same on all devices in a network.
Parameter range
0 - 1
Parameter Description
0 Disabled
1 Enabled
Default
0
KY (AES Encryption Key)
Sets the 256-bit network security key value that the device uses for encryption and decryption.
This command is write-only. If you attempt to read KY, the device returns an OK status.