XR500 Series Installation Guide Digital Monitoring Products
37
COMPLIANCE
False Alarm Reduction Programmable Options *
35.1 Shipping Defaults and Recommended Programming for ANSI/SIA CP-01-2010
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP XR500
PROGRAMMING
GUIDE LT-0679
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1 Exit Time 15.2 Exit Delay
Required
(Programmable)
45 sec. - 250 sec.
60
Seconds
60 Seconds
4.2.2.2 Progress
Annunciation
15.2 Exit Delay Allowed
Individual keypads
may be disabled per
zone
All
keypads
enabled
All keypads enabled
4.2.2.3 Exit Time Restart 15.2 Exit Delay Required Option
For re-entry during
exit time
Enabled Enabled
4.2.2.5 Auto Stay Arm on
Unvacated Premises
33.3 Occupied Premise
- See XR500 Install
Guide (LT-0681)
Required Option
(except for
remote arming)
Area 1 = Perimeter
Area 2 = Interior
Enabled
Enabled for Residential
Applications
4.2.4.4 Exit Time and
Progress Annunciation/
Disable - for Remote Arm
Not Available on
Remote Arming
Allowed Option
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1 Entry Delay(s) 8.3 Entry Delay
Required
(Programmable)
30 sec. – 240 Sec. **
30
Seconds
At least 30 Seconds **
4.2.5.1 Abort Window –
for Non-Fire Zones
3.7 Transmit Delay Required Option
Disable by zone or
zone type
Enabled
NT DY EX
Zone
Enabled
4.2.5.1 Abort Window
Time – for Non-Fire
Zones
3.7 Transmit Delay
Required
(Programmable
15 sec. - 45 sec. **
30
Seconds
At least 15 Seconds **
4.2.5.1.2 Abort
Annunciation
3.7 Transmit Delay Required Option
Annunciate that no
alarm was transmitted
(S45)
Yes Yes
4.2.5.4.1 Cancel
Annunciation
Always Enabled - Not
Programmable
Required Option
Annunciate that
a Cancel was
transmitted (S49)
Always
Enabled
Yes
4.2.6.1 & 4.2.6.2 Duress
Feature
User Code + 1 =
Ambush Code Not
Available
Allowed Option
No 1 + derivative of
another user code/no
duplicates with other
user codes
Code +1
Always
Disabled
Not Programmable
4.3.1 Cross Zoning 16.22 Cross Zone Required Option
Yes/No Zone
Programming
No
Enabled using two or
more programmed
zones
4.3.1 Programmable
Cross Zoning Time
8.4 Cross Zone Time Allowed 4 sec. - 250 sec. 4 Seconds
Per walk path in
protected premises
4.3.2 Swinger Shutdown
8.7 Swinger Bypass
Trips
Required
(Programmable)
1-6 trips 2 trips 2 trips
4.3.2 Swinger Shutdown
Disable
16.16 Swinger Bypass Allowed
For non-police
response zones
Yes Enabled (all zones)
4.3.3 Fire Alarm
Verication
16.4 Zone Type Required Option FV Type Zone No
Yes as required (unless
sensors can self verify)
4.5 Call Waiting Cancel
3.19 Telephone
Number
Required Option
Include *70P in
Telephone Number
Disabled
Enabled if user has
call waiting
4.6.3 System Test 17.5 Walk Test Allowed
Test all protection
devices
N/A N/A
4.6.5 Communications 17.5 Walk Test Not Allowed N/A N/A N/a
* Programming at installation may be subordinate to other listed requirements for the intended application.
** For listed Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR500N SERIES and is the answer not in the manual?

DMP Electronics XR500N SERIES Specifications

General IconGeneral
BrandDMP Electronics
ModelXR500N SERIES
CategoryControl Panel
LanguageEnglish

Related product manuals