Digital Monitoring Products XR500 Series Installation Guide
38
WIRING DIAGRAMS
False Alarm Reduction Programmable Options (continued)
35.2 Call Waiting
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P (pause), the
standard telephone code prex that cancels call waiting, into the telephone number string. Cancel Call Waiting for
telephone lines that have Call Waiting operational on the telephone line. See the XR500 Series Programming Guide
(LT-0679).
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
35.3 Occupied Premise
When only two areas are used, and area one is named Perimeter, and area two is named Interior, and no exit type
zone transition occurs during the exit delay because the premise continues to be occupied, the Interior area will
automatically disarm at the end of the exit delay.
35.4 Entry Delay
Only use Entry Delay 1. Do not use Entry Delay 2, 3, or 4. See the XR500 Series Programming Guide (LT-0679).
35.5 Minimum Installation Requirements
SIA CP-01-2010 minimum system installation requirements include an XR500, a listed local Bell, and o premise
DACT communication to an SCS-1R receiver plus one of the following compatible keypads.
630F Fire Command™ Center
7060, 7063, 7070, or 7073 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7160, 7163, 7170, or 7173 Thinline™ keypads