13.5.2 Aligning the flap clamps as to the pick-up folder
Standard checking
The flap clamp height above the fabric sliding sheet must amount to
14+3 mm
in swivelled-in position. The lateral distance of the flap
clamps to the pick-up folder has to be adjusted as close as possible
without touching it (Dimension
0.3+0.5 mm
).
(See sketch page 112)
Correction of the height (Dimension 14 + 3 mm)
Activate the output element
YC113
in the test program
Selecting the
output elements.
See also Programming Instructions, chapter 7.4.5.
The flap feeding devices swivel in.
Adjust the stop for the lowered position of the flap clamp lifting
device as described in chapter 13.5.3.
Loosen screws 1.
Turn the swivel arm 2.
Tighten the screws 1.
If required, readjust the shanks 3 and 4.
114
21
43
65