11.3 Lifting motion of the folder
Caution: Danger of injury !
Switch off the main switch.
Adjust the lifting motion of the folder only with the sewing unit
switched off.
Standard checking
When the folder is low ered
Lower the folder on the fabric sliding s heet. In this position there
must be a clearance of 0.3 - 0.5 mm between the guide roller 7 and
the lowest point of the guide groove 6.
When the folder is raised
When the folder is raised, there must still be some clearance between
the guide roller 7 and the highest point of the guide groove 6.
Press the folder down to the fabric sliding s heet by hand.
For this purpose turn the stop 8 back, if required.
Check the air gap between guide groove 6 and guide roller 7.
Lift the folder up to the upper stop 3.
Check the air gap between guide groove 6 and guide roller 7.
Correction
Swing the folding station out.
Adjust the stop 3 at the pivoting cylinder 4.
If - with the folder lowered - the guide roller 7 hits the guide groove and
the folder is not lowered as far as required, the guide groove has to be
readjusted (see next page).
3
87
65
21
43

Table of Contents

Other manuals for DURKOPP ADLER 745-34-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER 745-34-2 and is the answer not in the manual?

DURKOPP ADLER 745-34-2 Specifications

General IconGeneral
BrandDURKOPP ADLER
Model745-34-2
CategorySewing Machine
LanguageEnglish

Related product manuals