Setting the drive
Service Instructions 967 - 02.0 - 12/2015
29
2. Manually rotate the handwheel (2) by at least one turn before turning it
to 105° on the scale ( p. 20).
3. Press the OK key to confirm the set position.
4. Press the Esc key to exit parameter settings mode.