6.5.1.11 Sleep on Fault
Parameter Possible Values Default HHP Lite Std Adv
Sleep on Fault No / Yes Yes
Enables going to sleep if a fault condition is active. If set to no, the unit will not go to sleep,
but will signal the fault indefinitely.
Note
If the value of Sleep Timer is zero, the value of Sleep on Fault is ignored.
During a throttle fault or OONAPU (Out Of Neutral At Power Up) fault the controller will never go to sleep, even if
this parameter is set to 'Yes'.
6.5.1.12 Power Off after Sleep
Parameter Possible Values Default HHP Lite Std Adv
Power Off after Sleep No / Yes Yes
Enables powering the unit off automatically after sleeping for approximately 6 hours to
save battery power.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 75