EasyManuals Logo

Dynamic RHINO2 DS90 User Manual

Dynamic RHINO2 DS90
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
GBK51948 RHINO2
Installation Manual Issue 5
6.5.4 OEM Drive Limits
The OEM Drive Limits allow the OEM to set the maximum value that dealers can set several
drive performance parameters to. This allows OEMs to limit certain parameters for specific
scooter models. Dealers will not be able to set the value of these parameters higher or
lower than the limits given below.
6.5.4.1 Maximum Forward Speed Limit
Parameter Possible Values Default HHP Lite Std Adv
Maximum Forward Speed Limit 0 - 100 % 100 %
Sets the maximum value that can be set by a dealer for the Maximum Forward Speed
parameter. Set to 100 % for no effect.
6.5.4.2 Maximum Reverse Speed Limit
Parameter Possible Values Default HHP Lite Std Adv
Maximum Reverse Speed Limit 0 - 100 % 100 %
Sets the maximum value that can be set by a dealer for the Maximum Reverse Speed
parameter. Set to 100 % for no effect.
6.5.4.3 Minimum Forward Speed Limit
Parameter Possible Values Default HHP Lite Std Adv
Minimum Forward Speed Limit 0 - 100 % 0 %
Sets the minimum value that can be set by a dealer for the Lowest (Minimum) Forward
Speed parameter. Set to 0 % for no effect.
6.5.4.4 Minimum Reverse Speed Limit
Parameter Possible Values Default HHP Lite Std Adv
Minimum Reverse Speed Limit 0 - 100 % 0 %
Sets the minimum value that can be set by a dealer for the Lowest (Minimum) Reverse
Speed parameter. Set to 0 % for no effect.
6.5.4.5 Acceleration Limit
Parameter Possible Values Default HHP Lite Std Adv
Acceleration Limit 0 - 100 % 100 %
Sets the maximum value that can be set by a dealer for the Forward Acceleration and
Reverse Acceleration parameters. Set to 100 % for no effect.
6.5.4.6 Deceleration Limit
Parameter Possible Values Default HHP Lite Std Adv
Deceleration Limit 0 - 100 % 100 %
Sets the maximum value that can be set by a dealer for the Forward Deceleration and
Reverse Deceleration parameters. Set to 100 % for no effect.
Page 94 - Programming

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 DS90 and is the answer not in the manual?

Dynamic RHINO2 DS90 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2 DS90
CategoryController
LanguageEnglish

Related product manuals