GBK51948 RHINO2
Installation Manual Issue 5
Warning
Setting Reverse Deceleration too low or too high can result in a scooter that is unsafe. Test thoroughly after
programming to make sure that the scooter complies with local regulatory requirements for maximum
allowable braking distance.
6.5.3.7 Lowest (Minimum) Forward Speed
Parameter
Possible
Values
Default HHP Lite Std Adv
Lowest (Minimum) Forward
Speed
0 - 100 %
20 % (Profile1)20 % (Profile
2)
✓ ✓ ✓ ✓
This parameter is only used when Speed Limit Pot is set to 'Yes'.
Lowest (Minimum) Forward Speed sets the maximum speed in the forward direction when
the lowest speed has been selected with the speed limit pot (see 5.9.6 Speed Limit Pot
Connections ) and the throttle is fully deflected forward. Dealers can adjust this parameter
to the preference of an individual user or to the terrain that a specific scooter will be used
in.
Note
This parameter is used with a speed limit pot that is connected IN PARALLEL with the throttle, between 'Throttle
Positive' (pin 2) and 'Throttle Negative' (pin 8), and that has its wiper connected to pin 9 (speed limit pot input).
If the scooter has a speed limit pot that is connected IN SERIES with the throttle wiper, Lowest (Minimum)
Forward Speed is not used and Speed Limit Pot must be set to 'No'.
This parameter cannot be set lower than the value of the Minimum Forward Speed Limit parameter that has
been set by the scooter manufacturer.
6.5.3.8 Lowest (Minimum) Reverse Speed
Parameter Possible Values Default HHP Lite Std Adv
Lowest (Minimum) Reverse Speed 0 - 60 %
20 % (Profile1)
20 % (Profile 2)
✓ ✓ ✓ ✓
This parameter is only used when Speed Limit Pot is set to 'Yes'.
It sets the maximum speed in the reverse direction when the lowest speed has been
selected with the speed limit pot (see 5.9.6 Speed Limit Pot Connections ) and the throttle
is fully deflected reverse. Dealers can adjust this parameter to the preference of an
individual user or to the terrain that a specific scooter will be used in.
Note
This parameter cannot be set lower than the value of the Minimum Reverse Speed Limit parameter that has
been set by the scooter manufacturer.