EasyManuals Logo

Dynamic RHINO2 DS90 User Manual

Dynamic RHINO2 DS90
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
6.5.3.4 Maximum Reverse Speed
Parameter Possible Values Default HHP Lite Std Adv
Maximum Reverse Speed 20 - 100 % See Parameter Variations
Sets the maximum speed in the reverse direction when the highest speed has been
selected with the speed limit pot (see 5.9.6 Speed Limit Pot Connections ) and the throttle
is fully deflected reverse. Dealers can adjust this parameter to the preference of an
individual user or to the terrain that a specific scooter will be used in.
Note
This parameter cannot be set higher than the value of the Maximum Reverse Speed Limit parameter that has
been set by the scooter manufacturer.
6.5.3.5 Reverse Acceleration
Parameter Possible Values Default HHP Lite Std Adv
Reverse Acceleration 0 - 100 % See Parameter Variations
Sets how quickly the reverse speed increases after the throttle has been deflected reverse.
0 % From standstill, the scooter reaches full reverse speed in 10 s
100 % From standstill, the scooter reaches full reverse speed in 0.4 s
Low acceleration values give a softer performance and a less sensitive throttle response.
High acceleration values give a more aggressive performance and a fast throttle response.
Note
This parameter cannot be set higher than the value of the Acceleration Limit parameter that has been set by the
scooter manufacturer.
6.5.3.6 Reverse Deceleration
Parameter Possible Values Default HHP Lite Std Adv
Reverse Deceleration 0 - 100 %
50 % (Profile1)
50 % (Profile 2)
Sets how quickly the scooter slows down after:
l
the throttle has been released to neutral while driving reverse
l
the key switch is removed while driving in reverse
0 % From full reverse speed, the scooter stops in 10 s
100 % From full reverse speed, the scooter stops in 0.4s
Low deceleration values produce a gentle stop, but increase the braking distance. High
deceleration values produce a more aggressive stop, but can be uncomfortable. Adjust this
parameter to the preference of the user.
Note
This parameter cannot be set higher than the value of the Deceleration Limit parameter that has been set by
the scooter manufacturer.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 DS90 and is the answer not in the manual?

Dynamic RHINO2 DS90 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2 DS90
CategoryController
LanguageEnglish

Related product manuals