6.5.3.9 Soft Start Period
Parameter Possible Values Default HHP Lite Std Adv
Soft Start Period 0 - 2550ms 800ms
Whenever there is a change in speed demand, the soft start function temporarily reduces
the acceleration / deceleration rate during the time that is set with Soft Start Period. This
makes the acceleration / deceleration smoother, especially with high acceleration /
deceleration rates or high load compensation settings.
Higher values give a softer start, while lower
values give a more direct and harsh start.
To disable soft start completely, set Soft
Start Period to zero.
Figure 51: Soft-Start Period
Warning
Soft Start Period and Soft Finish values have the potential to impact the Emergency Deceleration rate.
Manufacturers should consider the impact of these values when setting the Emergency Deceleration rate to
ensure that required stopping distances can be achieved. It is recommended to set Soft Start Period and Soft
Finish values before finalising the Emergency Deceleration value.
6.5.3.10 Soft Finish
Parameter Possible Values Default HHP Lite Std Adv
Soft Finish 0 - 100 % 35 %
When the scooter almost reaches its desired speed during acceleration or deceleration, the
acceleration/deceleration rate is slowly decreased to zero. This prevents a sudden change
in acceleration once the desired speed is reached.
Use the Soft Finish parameter to adjust the
point where the soft transition starts.
0 % Direct and harsh transition (no soft
finish at all)
100 % Very smooth transition
For most applications, the default value of
35% works fine.
Figure 52: Soft Finish
Warning
Soft Start Period and Soft Finish values have the potential to impact the Emergency Deceleration rate.
Manufacturers should consider the impact of these values when setting the Emergency Deceleration rate to
ensure that required stopping distances can be achieved. It is recommended to set Soft Start Period and Soft
Finish values before finalising the Emergency Deceleration value.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 87