5. Programming on the device
5.3 Circuit diagram elements
5.3 Circuit diagram elements
A circuit diagram is a series of commands that the easyE4 device processes cyclically
in RUN operating mode.
Coils and contacts are interconnected in the circuit diagram. In RUN mode, a coil is
switched on or off depending on the power flow and coil function set.
5.3.1 Function blocks
Function blocks are program elements with special functions. Examples: Timing relays,
time switch, data block comparators. Function blocks are provided with or without con-
tacts and coils. How a safety or standard function block is added to the safety or stand-
ard circuit diagram and parameterized is described in
Section "Working with function blocks", page 154
In RUN mode the function blocks are processed according to the circuit diagram and
the results are updated accordingly.
Examples:
Timing relay = Function block with contacts and coils
Time switch = Function block with contacts
5.3.2 Relays
Relays are switching devices that are emulated in easyE4 device electronically, which
activate their contacts according to the assigned function. A relay consists of at least
one coil and contact.
124
easyE4 11/18 MN050009 EN www.eaton.com

Table of Contents

Other manuals for Eaton EASY-E4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton EASY-E4 Series and is the answer not in the manual?

Eaton EASY-E4 Series Specifications

General IconGeneral
TypeProgrammable Relay
Digital InputsUp to 12
Digital OutputsUp to 8
DisplayLCD
Operating Temperature-25°C to +55°C
Protection DegreeIP20
Storage Temperature-40°C to +70°C
Supply Voltage24 V DC, 100-240 V AC
Analog Inputs4
OutputsRelay, transistor
ProgrammingEASY-SOFT-PRO
CommunicationEthernet, Modbus, CANopen
ExpansionExpandable with additional modules
Relative Humidity5% to 95% (non-condensing)
StandardsIEC/EN 61131-2, UL 508, CSA C22.2 No. 142