13. Maintenance
13.3 Storage, transport and disposal
13.3 Storage, transport and disposal
13.3.1 Storage and transport
CAUTION
UV LIGHT
Plastics will become brittle when exposed to UV light. This artificial
aging will reduce the easyE4 unit's lifespan. Protect the device from dir-
ect sunlight and other sources of UV radiation.
CAUTION
SHORT-CIRCUIT HAZARD
If the device is or has been exposed to environmental fluctuations (ambi-
ent temperature, air humidity), condensation may form on or inside it. As
long as this condensation is present, there will be a short-circuit hazard.
Do not switch on the device when it has condensation in or on it.
If the device has condensation in or on it, or if the panel has been
exposed to environmental fluctuations, let the panel settle into the exist-
ing ambient temperature before switching it on.
The ambient conditions must be met when transporting and storing the easyE4.
The ambient air temperature for storage and transportation must not exceed the max-
imum specified limit:
Ambient climatic conditions
Air pressure (in operation) 795 - 1080 hPa
max. 2000 m NHN
Temperature
Operation
- 25 +55 °C (-13 +131 °F)
The display is readable between ϑ -5°C (-23°F) T 50°C (122°F).
Storage / Transport - 40 +70 °C (-40 +158 °F)
Humidity Relative humidity 5 - 95 %
Condensation Prevent condensation by means of suitable measures
Before commissioning
If storing/transporting the device in cold weather conditions or in
such a way that it will be exposed to extreme differences in tem-
perature, make sure that no condensation forms on or inside the
device.
If there is condensation in or on the device, do not switch on the
device until it is completely dry.
Use the original packaging to ship the device.
576
easyE4 11/18 MN050009 EN www.eaton.com

Table of Contents

Other manuals for Eaton EASY-E4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton EASY-E4 Series and is the answer not in the manual?

Eaton EASY-E4 Series Specifications

General IconGeneral
TypeProgrammable Relay
Digital InputsUp to 12
Digital OutputsUp to 8
DisplayLCD
Operating Temperature-25°C to +55°C
Protection DegreeIP20
Storage Temperature-40°C to +70°C
Supply Voltage24 V DC, 100-240 V AC
Analog Inputs4
OutputsRelay, transistor
ProgrammingEASY-SOFT-PRO
CommunicationEthernet, Modbus, CANopen
ExpansionExpandable with additional modules
Relative Humidity5% to 95% (non-condensing)
StandardsIEC/EN 61131-2, UL 508, CSA C22.2 No. 142