Appendix A2
M588-00-880 Issue E
A2.4 Menus
There are three menu buttons NORMAL, STATUS and SETUP described below.
NR in the data part of a parameter indicates no reading.
NP in the data part of a parameter indicates a parameter that is not present.
A2.4.1 Normal menu
This menu is displayed when the PDT is first plugged into the pump, or accessed by pressing the NORMAL button. Up
to 4 parameters are displayed, scroll by pressing up/down keys.
By default the 4 parameters displayed in the normal menu are as shown in Table A3 above. It is possible to change
the parameters displayed, refer to Appendix A2.5.
A2.4.2 Status menu
Press the STATUS button to enter. Scroll by pressing UP/DOWN keys. Press CANCEL to exit back to Normal menu.
If a device is not fitted the associated parameters will not be displayed. Parameters displayed:
Table A3 - Normal menu
Description Typical display
Serial Number S/N 1234567
Control Holder NONE IN CONTROL
Dry Pump current DP CURRENT 1.1 A
Booster current MB CURRENT 1.1 A
Table A4 - Typical display
Description Typical display
Serial Number S/N 1234567
Control Holder NONE IN CONTROL
Dry Pump current DP CURRENT 1.1 A
Booster current MB CURRENT 1.1 A
Green Mode state Green Mode STATE Off
Inlet isolation valve open/closed state ISOL VALVE Open
Dry pump stator reference temperature TCS REF 100 C
Dry Pump temperature DP TEMP 100 C
Dry Pump exhaust stage temperature DP EXH STG 63 C
Dry Pump End Cover temperature DP E/C TEMP 100 C
Booster temperature MB TEMP 100 C
Booster End Cover temperature MB EC TEMP 100 C
Nitrogen flow switch status N2 Supply OK
Dry Pump Power DP POWER 1.1 kW
Booster Power MB POWER 1.1 kW
Dry Pump speed in percent DP SPEED 100 %
Dry Pump speed in Hz DP SPEED 100 Hz